YR YRKS YRKK Series High Voltage Wound Rotor Induction Motor
time:2024-07-15 10:34 click:
Brand:WOLONG
Model: YR YRKK YRKS
Frame: 355 ~ 630mm
Power: 200-2800kW
Voltage: 6kV
Protection Grade: IP55
Cooling Method: IC611 IC616 IC666
Model: YR YRKK YRKS
Frame: 355 ~ 630mm
Power: 200-2800kW
Voltage: 6kV
Protection Grade: IP55
Cooling Method: IC611 IC616 IC666
contact +8613609288011
Product Detail
YR, YRKS, YRKK series of high voltage winding rotor three-phase asynchronous motors (frame number 355-630), our company latest products developed and produced by the department have advanced levels.This series of motors is made of sophisticated materials, excellent manufacture, high performance index, low noise, low vibration and reliability. Is easy to use, install and maintain.YR, YRKS, YRKK series of high voltage winding rotor three-phase asynchronous motors (frame number 355-630), our company latest products developed and produced by the department have advanced levels.This series of motors is made of sophisticated materials, excellent manufacture, high performance index, low noise, low vibration and reliability. Is easy to use, install and maintain.The cooling method of this series of motors is according to the standard of GB/T1993 and IEC34-6 "Motor cooling Method".For IC01, IC81W, IC611 three kinds, according to negotiation can also be made into IC616; The installation mode of this series motor is
Horizontal foot mounting (IMB3) structure, in accordance with GB/T997 and IEC34-7 "Rotating motor Structure and mounting type (IM Code name). If the user has other requirements, it can be negotiated separately.
Application
This series of motors can be used to drive a variety of general purpose machinery, such as compressors, pumps, crushers, cutting machines,transport machinery and blowers, coal mills, rolling machines, winches, belt machines, etc. Whether indoor, outdoor, high originality climate or hot and humid climate, this series of high-voltage three-phase asynchronous motors can always provide a driving force beyond the outstanding group.Model Description
YRKK-5603-4Three Phase Asynchronous Motor
Wound rotor
K K- Air to air cooling
560-Specification code, indicating that the shaft center height is 560mm
3-Core length code (# 3 core)
4-Poles
Implementation Standards
GB 755 rotary motor rating and performanceClassification of structure type, installation type and junction box position of GB/T 997 rotary motor (IM code)
GB/T 1032 three-phase asynchronous motor test method
GB/T 1993 Rotating motor cooling method
GB/T 4942.1 Protection class (IP code) classification of the overall structure of the rotating motor
GB 1971 Rotary motor line end mark and direction of rotation
GB/T 4772.2 Dimensions and output power levels of rotating motors - Part 2: Stand sizes 355 to 1000 and convex
Border numbers 1180 ~ 2360
GB 10068 - Measurement, assessment and limits of mechanical vibration for motors with a shaft center height of 56mm and above
GB/T 10069.1 Rotating motor noise determination methods and limits - Part 1: Rotating motor noise determination methods
GB 10069.3 Rotating motor noise determination methods and limits - Part 3: Noise limits
GB 14711 General safety requirements for small and medium-sized rotating motors
Basic Features
Frame number: 355 ~ 630Rated voltage: 6kV
Rated frequency: 50Hz
Rated power range: See Table 4 and Table 5
Poles: 4 ~ 12P
Heat Classification: 155(F)
Temperature rise limit: 80K(Class B), 105K(Class F)
Cooling methods: See Table 2
Installation Mode: IMB3
Protection level: See Table 2. Standard configuration: The collector ring of the motor is located on the outside of the bearing, protection level
The value is IP23. Optional configuration: If the user requires another type of protection class, or the collector ring is located on the inside of the bearing,
Special request must be made at the time of ordering.
Working system: S1
Ambient air temperature: -15℃ ~ +40℃
Altitude: ≤1000mm
Indoor (Standard configuration).
Optional: outdoor (W), outdoor medium corrosion (WF1), outdoor strong corrosion (WF2), indoor medium Corrosion (F1), indoor corrosion protection (F2), hot and humid zone (TH), dry tropical zone (TA), outdoor hot and humid zone (THW),Outdoor Dry Tropics (TAW).
Mounting
Parameter
Noise level
Recommend MORE+
-
TZYW series positive pressure brushless excitation
-
NEXP series explosion-proof Three-phase asynchronou
-
BPY-S30 series variable frequency speed regulation
-
YFBKK series for dust explosion-proof pulverizer
-
TBVF Ex permanent magnet synchronous variable frequ
-
YBRB series flameproof three-phase AC motor for pum
-
YBU YBUS YBUD series tunnel boring machine flamepro
-
YR YRKS YRKK Series High Voltage Wound Rotor Induct
NEWS MORE+
- The influence of the number of motor winding turns 2024-09-29
- Wolong Electric Drive Excellent Partner CEO Annual 2024-09-27
- Change of rotation direction of AC motor 2024-09-27
- The difference between explosion-proof marks Exd an 2024-09-26
- Working Principle and Standard of Motor Vibration S 2024-09-25
- What is the difference between IC81W and IC86W in A 2024-09-24
- The harm and inspection of pinholes on enameled wir 2024-09-23
- Does simulation technology affect motor performance 2024-09-20
- What are the basic characteristics of high-efficien 2024-09-19
- Why is differential protection used on large high-v 2024-09-18