Inspection and maintenance of explosion-proof motors
I. Appearance inspection: 1. Check whether the motor housing has cracks, open welding, deformation, whether the spare parts are complete and whether there is any damage. 2. Check whether the fasteners of the explosion-proof parts are complete, and whether the fastening screws and holes have slip buckles. II. Rotor inspection: After pulling out the rotor, remove the inner and outer small covers to check whether there is any damage. The rotor squirrel cage bars and end rings are welded firmly and reliably, and there must be no open welding or false welding. III. Bearing inspection: Remove the backrest wheel to check whether there is any damage, remove the bearing, and check whether there are any cracks, peeling, pitting, discoloration and rust spots. IV. Stator inspection: 1. The stator core and winding surface are clean, and the winding insulation should not have obvious damage and changes. 2. When the winding is fully rewound, the insulation level, winding pitch, wire cross-section, etc. should be the same as the original design. 3. Number of immersions: immersion is not less than 3 times. V. Cooling system: Check that the water channel of the water-cooled motor is unobstructed, the seal is intact, there is no leakage, and a good water pressure test is performed. 6. Explosion-proof surface inspection: The repair of each explosion-proof part of the explosion-proof motor complies with the GB3836.2-2000 standard. 7. Test: 1. Insulation resistance value of winding: should be lower than 5MΩ (660V, 380V), 1140V not less than 10MΩ. 2. Withstand voltage test: 380V-2000v/min, 660V-2500v/min, 1140V-3000v/min. 3. No-load test: The unbalanced value of the three-phase no-load current does not exceed 10%, and the operation is stable without abnormal noise.
When repairing explosion-proof motors, special attention should be paid to the following matters: 1. Safety First: There is a certain risk of fire and explosion when the explosion-proof motor is running, so the safety of personnel must be ensured during maintenance. Workers should wear personal protective equipment that meets safety requirements, such as protective clothing, safety helmets, protective glasses, etc. At the same time, the work area needs to be isolated to ensure that there are no flammable and explosive items around, and special explosion-proof tools and equipment should be used for maintenance. 2. Understand the structure and working principle of the motor: Before repairing the explosion-proof motor, you need to have some understanding of the structure and working principle of the motor. Be familiar with the various components of the motor and its functions, and conduct targeted inspections and repairs on the faults and points in it. 3. Regular inspection and maintenance: The explosion-proof motor will be affected by greater loads and the environment during operation, so regular inspection and maintenance are required. Clean the dust on the surface of the motor regularly, check whether the wiring of the motor is loose, check whether the bearings of the motor are well lubricated, etc. If a fault or abnormality is found, it should be repaired or replaced in time. 4. Check the power supply and power supply system of the explosion-proof motor: Before repairing the explosion-proof motor, it is necessary to check the normal operation of the power supply and power supply system. Ensure the stability of the power supply voltage and frequency, check whether the cable is damaged or aged, and ensure that the cable connector is firmly and reliably connected: 5. Strictly follow the maintenance process: When repairing explosion-proof motors, you need to follow a certain process and follow the corresponding operating procedures. First, you need to cut off the power supply, then inspect and repair the motor, and then conduct a trial run after the maintenance is completed. During the operation, you need to strictly follow the operating procedures to ensure the accuracy and safety of each step 6. Check the insulation condition of the motor: The insulation condition of the explosion-proof motor is crucial to its safe operation. During maintenance, you need to check the insulation condition of the motor, and use the insulation resistance star meter to test the insulation material to ensure that its insulation condition meets the requirements. If the insulation material is found to be aging, damaged, or the insulation resistance is too low, it should be replaced in time 7. Reasonable selection of lubricating materials: When repairing the bearings of explosion-proof motors, you need to select lubricating materials that meet the requirements. The selection of lubricating materials should be in line with the use environment and working conditions of the motor. At the same time, avoid using flammable and explosive lubricating materials to ensure the safe operation of the motor. 8. Check the grounding system of the motor: The grounding system of the explosion-proof motor is an important part of preventing the accumulation of static electricity and leakage of the motor. During maintenance, it is necessary to check whether the grounding system of the motor is normal, ensure that the grounding resistance meets the requirements, and avoid safety accidents caused by poor grounding. 9. Pay attention to the protection level of the explosion-proof motor: The protection level of the explosion-proof motor has an important impact on its safety. During maintenance, it is necessary to understand the protection level of the motor and operate in accordance with the requirements. It is particularly important to note that the shell of the explosion-proof motor cannot be disassembled at will to prevent the destruction of the explosion-proof structure. 10. Keep maintenance records: After the explosion-proof motor is overhauled, a complete maintenance record should be kept. The record should include the basic information of the motor, inspection results, maintenance measures, and the signature of the maintenance personnel. These records can be used as a basis for judging the operation of the motor and problem solutions in the future. In short, when inspecting explosion-proof motors, safety comes first, special attention should be paid to personnel safety, and operations should be carried out in accordance with the operating procedures. Check the insulation condition of the motor, the grounding system, and the selection of lubricating materials, etc., record the inspection process and results, and ensure the safe operation of the motor. At the same time, regular inspection and maintenance of explosion-proof motors are carried out to timely detect and eliminate faults and ensure the normal operation of the motors.
Recommend MORE+
-
YZYKK High Voltage Positive Pressure Asynchronous M
-
OLI Explosion-Proof Vibration Motors
-
YBC Coal Mine Flame-proof Motor
-
YB3 High-pressure explosion-proof motor
-
YB3 high voltage explosion-proof motor
-
YFB3 Low-voltage dust explosion-proof motor
-
YBRB Flame-proof AC Motor
-
Y3 series high voltage three-phase AC motor
NEWS MORE+
- Starting method of three-phase asynchronous motor 2024-11-22
- Analysis of the causes of three-phase AC motor burn 2024-11-21
- Analysis of the mean trouble-free working time of m 2024-11-20
- What is the function of current transformer? 2024-11-19
- Generation and Harm of Corona in High Voltage Motor 2024-11-18
- Energy-saving transformation of dust treatment scen 2024-11-15
- Why do low-pole-number motors often have phase-to-p 2024-11-14
- Introduction to commonly used motor drive modules 2024-11-13
- Differences between vertical and horizontal motor t 2024-11-12
- Wolong YBX series explosion proof three phase low v 2024-11-11