Is the number of poles of the motor rotor fixed?
source:未知 time:2024-09-06 11:51nbsp; click:
The number of rotor poles of a motor refers to the number of magnetic poles on the motor rotor; the number of rotor poles of a motor affects the motor speed and torque. For cage-type motors, the number of rotor poles is automatically sensed according to the number of stator poles; theoretically, the same cage-type rotor can cope with motor stators with different pole numbers, that is, the basic performance requirements of the motor can be met through induction matching. However, from the perspective of overall performance compliance, if the slot matching between the stator and the rotor is unreasonable, it may cause problems such as difficulty in starting the motor, starting dead points, and electromagnetic noise. Therefore, in the design of the motor rotor slot shape and number of slots, a relatively optimized slot matching relationship must also be selected.
For wound rotors, the design of the motor windings has fixed the matching relationship with the number of stator poles; for permanent magnet motor rotors, the number of poles is fixed by the arrangement of magnetic steel. Once the number of poles of this type of rotor is fixed, it will not change and can only match the stator with the same number of poles. In motor products, the number of stator poles and the number of rotor poles are important parameters of the motor. The number of stator poles determines the speed of the motor's rotating magnetic field, and the number of rotor poles must be the same as or match the stator. When the two are different or mismatched, the motor stator and rotor magnetic fields are not synchronized, and it is impossible to generate a fixed direction of torque to drive the device to operate.
low voltage electric motor, Ex motor, Motor manufacturers in China, three phase induction motor, Wolong Nanyang Explosion Protection
low voltage electric motor, Ex motor, Motor manufacturers in China, three phase induction motor, Wolong Nanyang Explosion Protection
上一篇:Reason the frequency converter causes the Ex motor to burn | 下一篇:Why can't the voltage withstand test be repeated?
Recommend MORE+
-
YB3 High-pressure explosion-proof motor
-
YZYKK High Voltage Positive Pressure Asynchronous M
-
OLI Explosion-Proof Vibration Motors
-
YBC Coal Mine Flame-proof Motor
-
YB3 high voltage explosion-proof motor
-
YFB3 Low-voltage dust explosion-proof motor
-
YBRB Flame-proof AC Motor
-
YQ-H series three-phase asynchronous marine motor
NEWS MORE+
- Why are three-phase asynchronous motors so commonly 2025-02-14
- Why are ordinary motors not suitable for direct use 2025-02-12
- EMA WPII the motor design standards 2025-02-11
- The difference between IC06 and IC511 cooling metho 2025-02-06
- Cone motor wiring diagram 2025-01-24
- Locked Rotor Torque and Starting Torque 2025-01-22
- The difference between pt100 and PTC 2025-01-20
- Principle and method of speed regulation of fan mot 2025-01-17
- Explosion-proof grade: Ex db ec pzc IIC T3 Gc 2025-01-15
- Motor magnetic center line 2025-01-13